- Home /
- Testing & Analysis /
- EMC Testing /
- Surge Generator Calibration
Surge Generator Calibration
Surge Generator calibration provides Open Circuit and Short Circuit waveform data that is compared to the requirements listed in IEC 61000-4-5, basic standard.
The table shown below describes our scope of accreditation for surge generator calibrations:
Open Circuit
Parameter/Equipment | Range | Best Uncertainty (±) | Comments |
---|---|---|---|
Voltage | (0 to 4) kV | 4.3% | IEC 61000-4-5 |
Front Time | 1.2 μs ± 30 % | 4.4% | IEC 61000-4-5 |
Duration Time | 50 μs ± 20 % | 4.3% | IEC 61000-4-5 |
Short Circuit
Parameter/Equipment | Range | Best Uncertainty (±) | Comments |
---|---|---|---|
Current | (12.5 to 100) A | 4.3% | IEC 61000-4-5 |
Front Time | 8 μs ± 20 % | 4.4% | IEC 61000-4-5 |
Duration Time | 20 μs ± 20 % | 4.3% | IEC 61000-4-5 |
- Antenna Calibration
- Attenuator Calibration
- Calibration Services for Measuring Test Equipment
- Coupling-Decoupling Networks Calibration
- Electrical Fast Transient Generator Calibration
- Electrostatic Discharge Generator Calibration
- LISN Calibration
- RF Pre-Amplifier Calibration
- Surge Generator Calibration
- Voltage Probe Calibration
- FAQ - Calibration